ES3002 Double Clamp Multi-function Earth Resistance Tester

ES3002 Double Clamp Multi-function Earth Resistance Tester

  • Resistance range : 0.01Ω-30KΩ
  • Soil resistance range : 0.0Ωm-9999KΩm
  • Current range : AC 0.0mA-1000A
  • Voltage range : AC 0.00V-600V
  • Measurement method: Precise four-wire、 three-wire measurement, simple two-wire measurement、Selection method, double clamp method for measuring grounding resistance

Technical Parameter

FunctionGround resistance、Soil resistivity、DC resistance、Ground voltage、AC current
Ambient temperature and humidity23℃±5℃,below 75%rh
Interference voltage<20V (should be avoided)
Interference current<2A (should be avoided)
Measure R electrode spacinga>5d
Measured ρelectrode spacinga>20h
Power8.4V lithium battery (built-in)
BacklightControllable  backlight, suitable for use in dim places
measurement modePrecise four-wire、 three-wire measurement, simple two-wire measurement、Selection method, double clamp method for measuring grounding resistance
Measurement methods2.3.4-wire method measurement: Polarization method, measuring current 20mA MaxSoil resistivity: four-pole method Selectivity Measurement: Polarization Method, Measuring Current 20mA MaxDouble clamp method: non-contact mutual inductance measurement method, test current 1mA MaxDC resistance: polarization methodAC current: average rectification (clamp)Ground Voltage: Average Rectification(between S-ES interface)
Test voltage waveformSine wave
Test frequency128Hz
Short circuit test currentAC 20mA max
Open circuit test voltageAC 28V max
Electrode spacing range1m~100m
Display mode4-bit large LCD display, with backlight
Measurement instructionsLED flashing indicator during measurement 
LCD size111mm×68mm
LCD display field108mm×65mm
Instrument sizeL/W/H:277.2mm×227.5mm×153mm
Clamp sizeL/T/H:101mm×27mm×214mm
Test line4 strips:red 15m,black 15m, yellow 10m,green 10m each one
Simple test line2strips:yellow 1.5m,green 1.5m each one
Auxiliary Grounding rod4PCS:φ10mm×200mm
Current clamp2PCS:Banana plug
Current clamp diameterφ50mm
Current clamp lead Length 2m
Measure timeAC current:about 2 times/sec;Ground voltage:about 2 times/sec;grounding resistance、soil resistivity: about 7 seconds/time
Line voltageMeasurement below AC100V (ground voltage measurement function cannot be used to measure commercial power)
USB interfaceWith USB interface, storage data can be uploaded to the computer, save and print
Communication LineOne USB communication line, 1.5m long
Data storage500 groups, “MEM” storage indicates, flashing “FULL” symbol indicates that the memory is full
Data reviewData review function: “MR” symbol display
Overflow displayOver-range overflow function: “OL” symbol display
Current clamp low current indicationWhen measuring by the selection method or the double-clamp method, when the current signal received by the current clamp A is lower than 0.5 mA, the symbol “    ” is displayed, and at this time, the clamping direction of the current clamp A should be checked.
Interference testAutomatic identification of interference signals, “NOISE” symbol indication when the interference voltage is higher than 5V
Auxiliary grounding testWith auxiliary ground resistance test function, 0.00KΩ ~ 30kΩ (Rh max = 3kΩ +100R <50kΩ; Rs max = 3kΩ +100R <50kΩ)
Alarm functionAlarm when the measured value exceeds the alarm setting value
Battery voltageReal-time display of battery power, reminding timely charging when battery voltage is low
Automatic Shutdown“APO” Indicates, automatic Shutdown After 15 Minutes
Power consumptionStandby: 40mA Max(Backlight off)
 Turn on backlight: 43mA Max
 measuring:120mA Max(Backlight off)
WeightInstrument: 2430g(with battery)
 Current clamp:940g(2PCS)
 Test lines:1300g(including simple test line)
 Auxiliary grounding rod: 850g(4PCS)
Working temperature and humidity-10℃~40℃;below 80%rh
Storage temperature and humidity-20℃~60℃;below 70%rh
Overload protectionGrounding resistance:AC 280V/3 seconds between H-E and S-ES ports
Insulation resistance20MΩ以上(500V between circuit and housing)
Pressure resistanceAC 3700V/rms(between circuit and housing)
Electromagnetic propertiesIEC61326(EMC)
Suitable for safety regulationsIEC61010-1(CAT Ⅲ 300V、CAT IV 150V、pollution level 2);IEC61010-031;IEC61557-1(grounding resistance);IEC61557-5(soil resistivity);JJG 366-2004.JJG 366-2004(ground resistance meter);JJG 1054-2009(Clamp grounding resistance meter).