FR3025 Series Digital Insulation Resistance Tester

FR3025 Series Digital Insulation Resistance Tester

  • Rated Voltage:100;250;500;1000;2500
  • Rated Voltage Accuracy: ±10%
  • Output short-circuit Current:≥2mA
  • Measurement Time Voltage: 2 times/sec, insulation resistance 7 seconds/time
  • Line Voltage:measure below AC600V

FR3025 Technical Parameter

FunctionInsulation resistance test, AC voltage test, DC voltage measurement
Ambient Temperature and Humidity23℃±5℃,below 75%rh
PowerDC 9V 6-section LR14 Dry Battery Standby for more than 100 hours
Rated Voltage100;250;500;1000;2500
Rated Voltage Accuracy±10%
Output short-circuit Current≥2mA
Absorption Ratio MeasurementHave
Polarization Index MeasurementHave
Test MethodDC voltage drop method
Test VoltageDC voltage measurement
Maximum Capacitive LoadOperates below 1uF
Shift GearAutomatic shifting
Back lightControllable gray backlight, suitable for use in dim places
Display Mode4 large LCD display, gray backlight
Measurement IndicationLED flashes during measurement
LCD Size108mm×65mm
Instrument SizeL/W/H:240mm×188mm×85mm
Test LineTest line: red 1 meter black 1 meter green 1 meter each
Measurement TimeVoltage 2 times/sec, insulation resistance 7 seconds/time
Line Voltagemeasure below AC600V
Data Storage500 groups,“MEM”storage instructions, display“FULL”symbol indicates that the storage is full
Data ReviewThe “MR” symbol indicates when looking up data
Overflow Display“OL” symbol indicates over-range overflow
Alarm FunctionAlarm when the measured value exceeds the alarm setting value
Battery VoltageLow battery voltage symbol, prompt battery replacement when battery voltage is low
Automatic Shutdown“APO”Indicate Automatic Shutdown After 15 Minutes
Power ConsumptionStandby: About 40mA (backlight off)
 Turn on backlight: about 43mA
 Measurement: about 75mA (backlight off)
WeightInstrument:1230g (Including battery)
Working Temperature and Humidity-10℃~40℃;Below 80%rh
Storage Temperature and Humidity-20℃~60℃;Below 70%rh
Insulation resistance200MΩ or more (500V between circuit and case)
Pressure ResistanceAC 5160V/rms(Between circuit and case)
Electromagnetic propertiesIEC61326(EMC)
Suitable for Safety RegulationsIEC61010-1(CAT Ⅲ 300V、CAT IV 150V、Pollution degree 2);

FR3025E Technical Parameter

FunctionInsulation resistance test, AC voltage test, DC voltage measurement
Ambient Temperature and Humidity23℃±5℃,below 75%rh
PowerDC 9V 6-section LR14 Dry Battery Standby for more than 100 hours
Rated Voltage250;500;1000;2500;5000
Rated Voltage Accuracy±10%
Output short-circuit Current≥2mA
Absorption Ratio MeasurementHave
Polarization Index MeasurementHave
Test MethodDC voltage drop method
Test VoltageDC voltage measurement
Maximum Capacitive LoadOperates below 1uF
Shift GearAutomatic shifting
Back lightControllable gray backlight, suitable for use in dim places
Display Mode4 large LCD display, gray backlight
Measurement IndicationLED flashes during measurement
LCD Size108mm×65mm
Instrument SizeL/W/H:240mm×188mm×85mm
Test LineHigh pressure rod: red 1 meterTest line: black 1 meter green 1 meter
Measurement TimeVoltage 2 times/sec, insulation resistance 7 seconds/time
Line Voltagemeasure below AC600V
Data Storage500 groups,“MEM”storage instructions, display“FULL”symbol indicates that the storage is full
Data ReviewThe “MR” symbol indicates when looking up data
Overflow Display“OL” symbol indicates over-range overflow
Alarm FunctionAlarm when the measured value exceeds the alarm setting value
Battery VoltageLow battery voltage symbol, prompt battery replacement when battery voltage is low
Automatic Shutdown“APO”Indicate Automatic Shutdown After 15 Minutes
Power ConsumptionStandby: About 40mA (backlight off)
 Turn on backlight: about 43mA
 Measurement: about 75mA (backlight off)
WeightInstrument:1230g (Including battery)
Working Temperature and Humidity-10℃~40℃;Below 80%rh
Storage Temperature and Humidity-20℃~60℃;Below 70%rh
Insulation resistance200MΩ or more (500V between circuit and case)
Pressure ResistanceAC 5160V/rms(Between circuit and case)
Electromagnetic propertiesIEC61326(EMC)
Suitable for Safety RegulationsIEC61010-1(CAT Ⅲ 300V、CAT IV 150V、Pollution degree 2);