FR2010E+ Double Clamp Digital Phase Voltammeter

FR2010E+ Double Clamp Digital Phase Voltammeter

  • Voltage range: AC 0.00V~600V
  • Current range: AC 0.0mA~20.0A
  • Phase range:0.0°~360.0°
  • Frequency range:45.00Hz~65.00Hz
  • Active power range:-12kW~12kW

Technical Parameter

FunctionMeasure two AC voltages, currents, phase between voltages, phase between currents, phases between voltages and currents, frequencies, active power, reactive power, apparent power, power factor, determine transformer wiring groups, inductive, capacitive circuits, test secondary loops and bus differential protection system, read out the phase relationship between the CTs of the differential protection groups, check the wiring of the power meter, check the line equipment, etc.
PowerDC3.7V large capacity lithium rechargeable battery
Power consumptionTurn on the backlight and consume up to 280mA. The battery can work continuously for more than 5 hours.
Display modeLCD display,71*52mm
Instrument sizeL/W/T:187*191*51mm
Voltage rangeAC 0.00V~600V
Current rangeAC 0.0mA~20.0A
Phase range0.0°~360.0°
Frequency range45.00Hz~65.00Hz
Active power range-12kW~12kW
Reactive power range-12kVAR~12kVAR
Apparent power range0.0~12kVA
Power factor range-1~+1
ResolutionVoltage:AC 0.01V
 Current:AC 0.1mA
 Phase:0.1°
 Frequency:0.01Hz
 Active power:0.1W
 Reactive power:0.1VAR
 Apparent power:0.1VA
 Power factor:0.001
Detection rateAbout 2 seconds/time
Data holdPress HOLD key to hold data during test, “HOLD” symbol display
Data storage500 groups
USB interfaceUSB interface, uploading data to a computer for analysis of management data
Automatic shut-downAbout 15 minutes after power on, the meter will automatically shut down to reduce battery consumption
Backlight functionSuitable for dim places and night use
Voltage detectionWhen the battery voltage is lower than 3V, the low battery voltage will display, remind to charge in time
Instrument weightHose:450g(including battery)
 Tip-shaped current clamp:170g×2
 Test line:250g
Test line length1.5m
Line length of the current clamp2m
Working temperature and humidity-10℃~40℃;below 80%Rh
Storage temperature and humidity-10℃~60℃;below 70%Rh
input impedanceTest voltage input impedance is:2MΩ
Pressure resistanceThe withstand voltage of 1000V/50Hz sine wave AC voltage between the instrument circuit and the housing lasts 1 minute
insulationBetween instrument line and housing≥100MΩ
structureDouble insulation
Suitable for safety regulationsIEC61010-1 CAT Ⅲ 600V,IEC61010-031,IEC61326,Pollution level 2