ES2080 Series Wireless H-Voltage Phasing Tester

ES2080 Series Wireless H-Voltage Phasing Tester

  • Detect phase votage : 220V-220kv
  • Phase range: 0.0°~360.0°
  • Phase range: o.0°~360.0°
  • Voltage range: 220V~35kV
  • Transmit frequence: 433MHz、31 5MHz
  • Differentiate qualitative: in phase: -25°-25°out of phase: 95°-145°or 215°- 265°
  • Phase indication: phasor diagram and digital display simultaneously

Technical Parameter

FeaturesFrequency measurement, phase measurement, phase sequence display, voltage measurement, voltage inspection
power supplyHost: DC7.5V, 5 AA alkaline batteriesDetector: zinc-manganese dry battery 6F22, 9V
Baseline conditions23℃±5℃, below 75%rh
PhasingContact phasing: The bare wire below 35kV or the wire with insulating sheath below 550kV can contact the wire core phase non-contact phasing.When the bare line voltage exceeds 35kV, a non-contact test must be used, and the probe is gradually approached to the core phase of the conductor
Transmission distanceWireless transmission, straight-line transmission distance of about 30 meters
Differential characterizationIn-phase: -30°~30°Out-of-phase: 90°~150° and 210°~270°
Phasing voltage70V~550kV
Phase range0.0°~360.0°; Accuracy: ≤±12°; Resolution: 0.1°
Frequency range45.0Hz~65.0Hz; Accuracy: ≤±2Hz; Resolution: 0.1Hz
*Voltage range70V~110kV; Accuracy: ±15%±5dgt Resolution: 100V
*Voltage accuracyHigh-voltage overhead line ±15%±5dgt (other applications: ±25%±5dgt)
transmit frequency433MHz, 315MHz
display mode3.5 inch color screen
LCD display size72mm×55mm
Meter size Host 187×119×48mm
 Detector 146×100mm
Phase indicationSimultaneous display of phasor diagram and numbers
Work instructionsWhen phase checking, the detector has sound and light indication function, red double flashing light indication and “beep-beep-beep” beep
data storage100 groups, flashing “FULL” symbol indicates that the storage is full
Data accessData access function: “READ” symbol display
Power consumption Detector: 70mA Max Max
 Host: 150mA Max
Instrument quality Detector: about 250g (including hook and battery)
 Host: about 450g (including battery)
battery voltageThe battery voltage is insufficient, and the low battery symbol ”     ” is displayed
Automatic shut-downThe meter shuts down after 15 minutes of inactivity
Insulation rod lengthMaximum diameter Φ38mm; Length: 800mm in contracted state; 3015mm in extended state
Insulation testBoth ends of the insulating rod after stretching: AC 220kV/rms; host and detector: AC3700V/rms (between exposed metal and plastic casing)
Suitable for safety regulationsGB13398-92, GB311.1-311.6-8, 3DL408-91 standards and the newly promulgated national electric power industry standard “General Specifications DL/T971-2005 for 1kV ~ 35kV Portable Phase checking Apparatus for Live Work”
 Comply with IEC61481-A2; 2004; IEC 61243-1