FR3060 Portable Reisistance tester 1A

FR3060 Portable Reisistance tester 1A

  • measure time: About 2 times/sec
  • USB interface:With micro USB interface
  • Data storage:500 groups, “MEM” storage indication, display “FULL” symbol to indicate storage is full
  • Test current ≥1A
  • Detection method:Four-wire method test

Model Comparison

ModelFR3060AFR3060FR3060C
Resistance Range0.01mΩ~30.00KΩ0.001mΩ~300.0KΩ0.01mΩ~10.00KΩ
Resolution10uΩ1uΩ10uΩ
Accuracy±0.1%FS±0.1%FS±0.1%FS
Data storage500 sets500 sets500 sets
USB Data upload functionNYN
Charging functionYYY

Technical Parameter

FunctionMainly used to measure the wire resistance of cables, the contact resistance of switches, connectors, relays, the resistance of coils, motors, transformer winding and metal riveting resistance, the connection resistance test between metal components, the low-value resistance test, and the grounding grid Resistance test of connecting conductor, contact resistance test, etc.
Detection methodFour-wire method test
Test current≥1A
Open circuit voltage≤4.2V
Overload protectionY
PowerMeasuring power≤8W
power supplyDC 3.7V 2500mAh
BacklightControllable gray and white screen backlight, suitable for dim places
Display ModelLCD
LCD Size72 mm×55mm
Instrument size187 mm×119 mm×50mm
Test line length60cm,red, black 1pcs
measure timeAbout 2 times/sec
USB interfaceWith micro USB interface
Communication linemicro USB 1pcs
Data storage500 groups, “MEM” storage indication, display “FULL” symbol to indicate storage is full
Data reviewData review function:“MR”symbol display
Overflow displayOver-range overflow function: “OL” symbol display
Battery voltageReal-time display of battery power, reminding timely charging when battery voltage is low
Automatic shut-down“APO” indicates, automatic shutdown after 15 minutes
Power consumptionStandby: about 100mA (backlight off)
 Turn on backlight: about 105mA
 Measure:2A Max(backlight off)
WeightInstrument:480g(including battery)
 Test line:250g
Working temperature and humidity-10℃~50℃;below 80%rh
Storage temperature and humidity-20℃~60℃;below 70%rh
Overload protectionAC 220V/0.0001 second between C1-C2 P1-P2 ports, after overload protection, you need to restart the meter to test normally
Insulation resistanceMore than 10MΩ(Between circuit and case 500V)
Pressure resistanceAC 3700V/rms(Between circuit and case)
Electromagnetic propertiesIEC61010-4-3,Wireless frequency electromagnetic field≤1V/m
Suitable for Safety RegulationsIEC61010-1, CAT III 600V, Pollution Level 2, JJG724-1991 “Determination of Direct Current Digital Ohmmeter”, JJG166-1993 “Dialect Resistor Verification Regulation”, “DL/T967-2005 Loop Resistance Tester and DC Resistance Fast Tester Verification Procedures